Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
1.
N Engl J Med ; 2024 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-38587261

RESUMEN

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).

5.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38099912

RESUMEN

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Valor Predictivo de las Pruebas , Recuperación de la Función , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Masculino , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Resultado del Tratamiento , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Anciano , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Factores de Tiempo , Anciano de 80 o más Años , Prótesis Valvulares Cardíacas , Estudios de Factibilidad , Medición de Riesgo , Diseño de Prótesis , Ecocardiografía Tridimensional
6.
Artículo en Inglés | MEDLINE | ID: mdl-37962288

RESUMEN

BACKGROUND: The CLASP IID (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical) trial is the first randomized controlled trial comparing the PASCAL system and the MitraClip system in prohibitive risk patients with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: The study sought to report primary and secondary endpoints and 1-year outcomes for the full cohort of the CLASP IID trial. METHODS: Prohibitive-risk patients with 3+/4+ DMR were randomized 2:1 (PASCAL:MitraClip). One-year assessments included secondary effectiveness endpoints (mitral regurgitation [MR] ≤2+ and MR ≤1+), and clinical, echocardiographic, functional, and quality-of-life outcomes. Primary safety (30-day composite major adverse events [MAE]) and effectiveness (6-month MR ≤2+) endpoints were assessed for the full cohort. RESULTS: Three hundred patients were randomized (PASCAL: n = 204; MitraClip: n = 96). At 1 year, differences in survival, freedom from heart failure hospitalization, and MAE were nonsignificant (P > 0.05 for all). Noninferiority of the PASCAL system compared with the MitraClip system persisted for the primary endpoints in the full cohort (For PASCAL vs MitraClip, the 30-day MAE rates were 4.6% vs 5.4% with a rate difference of -0.8% and 95% upper confidence bound of 4.6%. The 6-month MR≤2+ rates were 97.9% vs 95.7% with a rate difference of 2.2% and 95% lower confidence bound (LCB) of -2.5%, for, respectively). Noninferiority was met for the secondary effectiveness endpoints at 1 year (MR≤2+ rates for PASCAL vs MitraClip were 95.8% vs 93.8% with a rate difference of 2.1% and 95% LCB of -4.1%. The MR≤1+ rates were 77.1% vs 71.3% with a rate difference of 5.8% and 95% LCB of -5.3%, respectively). Significant improvements in functional classification and quality of life were sustained in both groups (P <0.05 for all vs baseline). CONCLUSIONS: The CLASP IID trial full cohort met primary and secondary noninferiority endpoints, and at 1 year, the PASCAL system demonstrated high survival, significant MR reduction, and sustained improvements in functional and quality-of-life outcomes. Results affirm the PASCAL system as a beneficial therapy for prohibitive-surgical-risk patients with significant symptomatic DMR.

7.
JACC Cardiovasc Interv ; 16(23): 2820-2832, 2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-37905772

RESUMEN

BACKGROUND: Favorable 6-month outcomes from the CLASP IID Registry (Edwards PASCAL transcatheter valve repair system pivotal clinical trial) demonstrated that mitral valve transcatheter edge-to-edge repair with the PASCAL transcatheter valve repair system is safe and beneficial for treating prohibitive surgical risk degenerative mitral regurgitation (DMR) patients with complex mitral valve anatomy. OBJECTIVES: The authors sought to assess 1-year safety, echocardiographic and clinical outcomes from the CLASP IID Registry. METHODS: Patients with 3+ or 4+ DMR who were at prohibitive surgical risk, had complex mitral valve anatomy based on the MitraClip Instructions for Use, and deemed suitable for treatment with the PASCAL system were enrolled prospectively. Safety, clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. Study oversight included a central screening committee, echocardiographic core laboratory, and clinical events committee. RESULTS: Ninety-eight patients were enrolled. One-year Kaplan-Meier (KM) estimates of freedom from composite major adverse events, all-cause mortality, and heart failure hospitalization were 83.5%, 89.3%, and 91.5%, respectively. Significant mitral regurgitation (MR) reduction was achieved at 1 year (P < 0.001 vs baseline) including 93.2% at MR ≤2+ and 57.6% at MR ≤1+ with improvements in related echocardiographic measures. NYHA functional class and Kansas City Cardiomyopathy Questionnaire score also improved significantly (P < 0.001 vs baseline). CONCLUSIONS: At 1 year, treatment with the PASCAL system demonstrated safety and significant MR reduction, with continued improvement in clinical, echocardiographic, functional, and quality-of-life outcomes, illustrating the value of the PASCAL system in the treatment of prohibitive surgical risk patients with 3+ or 4+ DMR and complex mitral valve anatomy.


Asunto(s)
Cateterismo Cardíaco , Insuficiencia de la Válvula Mitral , Humanos , Cateterismo Cardíaco/efectos adversos , Ecocardiografía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento , Ensayos Clínicos como Asunto
8.
J Am Coll Cardiol ; 82(22): 2101-2109, 2023 11 28.
Artículo en Inglés | MEDLINE | ID: mdl-37877909

RESUMEN

BACKGROUND: The American College of Cardiology/American Heart Association guidelines recommend the assessment and grading of severity of aortic stenosis (AS) as mild, moderate, or severe, per echocardiogram, and recommend aortic valve replacement (AVR) when the AS is severe. OBJECTIVES: The authors sought to describe mortality rates across the entire spectrum of untreated AS from a contemporary, large, real-world database. METHODS: We analyzed a deidentified real-world data set including 1,669,536 echocardiographic reports (1,085,850 patients) from 24 U.S. hospitals (egnite Database, egnite). Patients >18 years of age were classified by diagnosed AS severity. Untreated mortality and treatment rates were examined with Kaplan-Meier (KM) estimates, with results compared using the log-rank test. Multivariate hazards analysis was performed to assess associations with all-cause mortality. RESULTS: Among 595,120 patients with available AS severity assessment, the KM-estimated 4-year unadjusted, untreated, all-cause mortality associated with AS diagnosis of none, mild, mild-to-moderate, moderate, moderate-to-severe, or severe was 13.5% (95% CI: 13.3%-13.7%), 25.0% (95% CI: 23.8%-26.1%), 29.7% (95% CI: 26.8%-32.5%), 33.5% (95% CI: 31.0%-35.8%), 45.7% (95% CI: 37.4%-52.8%), and 44.9% (95% CI: 39.9%-49.6%), respectively. Results were similar when adjusted for informative censoring caused by treatment. KM-estimated 4-year observed treatment rates were 0.2% (95% CI: 0.2%-0.2%), 1.0% (95% CI: 0.7%-1.3%), 4.2% (95% CI: 2.0%-6.3%), 11.4% (95% CI: 9.5%-13.3%), 36.7% (95% CI: 31.8%-41.2%), and 60.7% (95% CI: 58.0%-63.3%), respectively. After adjustment, all degrees of AS severity were associated with increased mortality. CONCLUSIONS: Patients with AS have high mortality risk across all levels of untreated AS severity. Aortic valve replacement rates remain low for patients with severe AS, suggesting that more research is needed to understand barriers to diagnosis and appropriate approach and timing for aortic valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Ecocardiografía , Índice de Severidad de la Enfermedad , Factores de Riesgo
9.
Circ Cardiovasc Interv ; 16(8): e012875, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37503662

RESUMEN

BACKGROUND: Depression and cognitive dysfunction (CD) are not routinely screened for in patients before transcatheter aortic valve replacement (TAVR) and their association with postprocedural outcomes is poorly understood. The objectives of this study are to determine the prevalence of depression and CD in patients with aortic stenosis undergoing TAVR and evaluate their association with mortality and quality of life. METHODS: We analyzed a prospective, multicenter TAVR registry that systematically screened patients for preexisting depression and CD with the Patient Health Questionnaire-2 and Mini-Cog, respectively. The associations with mortality were assessed with Cox proportional hazard models and quality of life (Kansas City Cardiomyopathy Questionnaire and EuroQol visual analogue scale) were evaluated using multivariable ordinal regression models. RESULTS: A total of 884 patients were included; median follow-up was 2.88 years (interquartile range=1.2-3.7). At baseline, depression was observed in 19.6% and CD in 31.8%. In separate models, after adjustment, depression (HR, 1.45 [95% CI, 1.13-1.86]; P<0.01) and CD (HR, 1.27 [95% CI, 1.02-1.59]; P=0.04) were each associated with increased mortality. Combining depression and CD into a single model, mortality was greatest among those with both depression and CD (n=62; HR, 2.06 [CI, 1.44-2.96]; P<0.01). After adjustment, depression was associated with 6.6 (0.3-13.6) points lower on the Kansas City Cardiomyopathy Questionnaire 1-year post-TAVR and 6.7 (0.5-12.7) points lower on the EuroQol visual analogue scale. CD was only associated with lower EuroQol visual analogue scale. CONCLUSIONS: Depression and CD are common in patients that undergo TAVR and are associated with increased mortality and worse quality of life. Depression may be a modifiable therapeutic target to improve outcomes after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Cardiomiopatías , Disfunción Cognitiva , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Calidad de Vida , Estudios Prospectivos , Depresión/diagnóstico , Depresión/epidemiología , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/epidemiología , Disfunción Cognitiva/diagnóstico , Disfunción Cognitiva/epidemiología , Disfunción Cognitiva/etiología , Atención Dirigida al Paciente , Cardiomiopatías/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
10.
Int J Cardiovasc Imaging ; 39(9): 1677-1685, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37347380

RESUMEN

Although it is assumed that more severe MR is associated with a greater burden of symptoms and lower exercise capacity, the relationship between symptoms, exercise capacity, and mitral regurgitant severity has not been well studied. We prospectively studied 67 (63 ± 11 years, 72% male) patients with at least mild degenerative MR and left ventricular ejection fraction ≥ 50% who underwent stress echocardiography, CMR, and evaluation with the Kansas City Cardiomyopathy questionnaire (KCCQ). Symptoms and exercise capacity were evaluated in the context of MR severity. Patients reporting dyspnea had lower KCCQ symptom scores (79 ± 23 vs. 96 ± 9, p = 0.01) and achieved lower percentage of age and gender predicted METs (114 ± 37 vs. 152 ± 43%, p < 0.001) compared to those without dyspnea. There was no significant difference in MR volume between those with vs. without dyspnea by CMR (43 ± 26 ml vs. 51 ± 28 ml, p = 0.3) or echocardiography (64 ± 28 vs. 73 ± 41ml, p = 0.4). Those with severe MR by CMR had similar KCCQ symptom scores (96 ± 10 vs. 89 ± 17, p = 0.04) and percentage of age and gender predicted METs (148 ± 42 vs. 133 ± 47%, p = 0.2) to those without severe MR. Those with severe MR by echocardiography had similar KCCQ symptom score (93 ± 15 vs. 89 ± 16, p = 0.3) and percentage of age and gender predicted METs (138 ± 43 vs. 153 ± 46%, p = 0.2) to those without severe MR. Patients with degenerative MR assessed by CMR and stress echocardiography, there was no relationship between MR severity and either symptoms or exercise capacity. These findings highlight the disconnect between symptoms and the severity of MR and challenge the assumption that correcting MR can be counted on to improve symptom status in patients with degenerative MR.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Masculino , Femenino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/complicaciones , Volumen Sistólico , Función Ventricular Izquierda , Tolerancia al Ejercicio , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad
13.
Curr Cardiol Rep ; 25(3): 89-95, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36787025

RESUMEN

PURPOSE OF REVIEW: This review summarizes the current management of patients with newly diagnosed aortic stenosis. RECENT FINDINGS: Recent developments include detection of early myocardial dysfunction using serum B-type natriuretic peptide levels and global longitudinal strain, as well as ongoing trials of transcatheter aortic valve replacement in asymptomatic patients and patients with moderate aortic stenosis complicated by symptoms or left ventricular systolic dysfunction. Given the high mortality associated with severe symptomatic aortic stenosis, all symptomatic patients should be referred for aortic valve replacement. Asymptomatic patients with left ventricular systolic dysfunction, abnormal exercise stress test, high degree of stenosis, rapid disease progression, or elevated serum B-type natriuretic peptide level may also have an indication for valve replacement, based on established criteria. The progress in management of severe aortic stenosis has been in the direction of earlier detection and earlier valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica , Disfunción Ventricular Izquierda , Humanos , Péptido Natriurético Encefálico , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Válvula Aórtica/cirugía , Medición de Riesgo , Índice de Severidad de la Enfermedad
14.
J Am Coll Cardiol ; 81(5): 431-442, 2023 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-36725171

RESUMEN

BACKGROUND: Mitral valve transcatheter edge-to-edge repair is safe and effective in treating degenerative mitral regurgitation (DMR) patients at prohibitive surgical risk, but outcomes in complex mitral valve anatomy patients vary. OBJECTIVES: The PASCAL IID registry assessed safety, echocardiographic, and clinical outcomes with the PASCAL system in prohibitive risk patients with significant symptomatic DMR and complex mitral valve anatomy. METHODS: Patients in the prospective, multicenter, single-arm registry had 3+ or 4+ DMR, were at prohibitive surgical risk, presented with complex anatomic features based on the MitraClip instructions for use, and were deemed suitable for the PASCAL system by a central screening committee. Enrolled patients were treated with the PASCAL system. Safety, effectiveness, and functional and quality-of-life outcomes were assessed. Study oversight also included an echocardiographic core laboratory and clinical events committee. RESULTS: The study enrolled 98 patients (37.2% ≥2 independent significant jets, 15.0% severe bileaflet/multi scallop prolapse, 13.3% mitral valve orifice area <4.0 cm2, and 10.6% large flail gap and/or large flail width). The implant success rate was 92.9%. The 30-day composite major adverse event rate was 11.2%. At 6 months, 92.4% patients achieved MR ≤2+ and 56.1% achieved MR ≤1+ (P < 0.001 vs baseline). The Kaplan-Meier estimates for survival, freedom from major adverse events, and heart failure hospitalization at 6 months were 93.7%, 85.6%, and 92.6%, respectively. Patients experienced significant symptomatic improvement compared with baseline (P < 0.001). CONCLUSIONS: The outcomes of the PASCAL IID registry establish the PASCAL system as a useful therapy for prohibitive surgical risk DMR patients with complex mitral valve anatomy. (PASCAL IID Registry within the Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID] NCT03706833).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Cateterismo Cardíaco/efectos adversos
15.
J Am Coll Cardiol ; 81(8): 743-752, 2023 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-36813373

RESUMEN

BACKGROUND: The extent of extravalvular cardiac damage is associated with increased risk of adverse events among patients with severe aortic stenosis undergoing aortic valve replacement (AVR). OBJECTIVES: The goal was to describe the association of cardiac damage on health status before and after AVR. METHODS: Patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were pooled and classified by echocardiographic cardiac damage stage at baseline and 1 year as previously described (stage 0-4). We examined the association between baseline cardiac damage and 1-year health status (assessed by the Kansas City Cardiomyopathy Questionnaire Overall Score [KCCQ-OS]). RESULTS: Among 1,974 patients (794 surgical AVR, 1,180 transcatheter AVR), the extent of cardiac damage at baseline was associated with lower KCCQ scores both at baseline and at 1 year after AVR (P < 0.0001) and with increased rates of a poor outcome (death, KCCQ-OS <60, or a decrease in KCCQ-OS of ≥10 points) at 1 year (stages 0-4: 10.6% vs 19.6% vs 29.0% vs 44.7% vs 39.8%; P < 0.0001). In a multivariable model, each 1-stage increase in baseline cardiac damage was associated with a 24% increase in the odds of a poor outcome (95% CI: 9%-41%; P = 0.001). Change in stage of cardiac damage at 1 year after AVR was associated with the extent of improvement in KCCQ-OS over the same period (mean change in 1-year KCCQ-OS: improvement of ≥1 stage +26.8 [95% CI: 24.2-29.4] vs no change +21.4 [95% CI: 20.0-22.7] vs deterioration of ≥1 stage +17.5 [95% CI: 15.4-19.5]; P < 0.0001). CONCLUSIONS: The extent of cardiac damage before AVR has an important impact on health status outcomes, both cross-sectionally and after AVR. (PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - XT Intermediate and High Risk (PII A), NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII B [PARTNERII B], NCT02184442; PARTNER 3 Trial: Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [P3], NCT02675114).


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Calidad de Vida , Resultado del Tratamiento , Estado de Salud , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Índice de Severidad de la Enfermedad
17.
JAMA Cardiol ; 7(12): 1253-1258, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36223091

RESUMEN

Importance: Internal medicine residents' professional development preferences were discordant with their perceptions of cardiology in a survey circulated a decade ago; no contemporary data exist. This information is important for effective recruitment and retention of a highly talented and diverse future cardiology workforce. Objective: To identify residents' professional development preferences and cardiology perceptions, in relation to specialty choice, and compare the findings with those from a decade prior. Design, Setting, and Participants: The original survey from the 2010 study was updated and sent to US internal medicine programs. Respondents (ie, internal medicine residents) rated 38 professional development preferences and 20 cardiology perceptions. Data were collected in 2020 and compared with survey results from the prior 2010 study. Multivariable models were created for specialty choice using scaled independent variables dichotomized using the top 2 options; categorical variables were recoded into binary variables for analysis. Main Outcomes and Measures: Multivariable models were used to determine the association of demographic characterisitcs and survey responses with prospective career choice. Responses were examined by total group, by gender, by self-reported consideration of entering cardiology as a profession, and by comparison with a decade prior both as a group and by gender. Results: A total of 840 residents (mean [SD] age, 29.24 [2.82] years; 49.8% male; 55.4% White) completed the survey. The survey incorporated a 5-point Likert scale of 1 (not important) to 5 (extremely important) for some of the questions, with additional questions on demographic characteristics. The most important professional development preferences by descending Likert score were as follows: positive role models (4.56), stimulating career (3.81), and family friendly (3.78). The cardiology perception statements with the highest agreement were as follows: interferes with family life during training (3.93) and having met positive role models or having positive views of cardiovascular disease as a topic (3.85). Multivariable analysis yielded a 22-element model predicting cardiology as career choice. Compared with the 2010 survey, the findings of this survey indicated increased importance of work-life balance components for both male and female residents, with a greater change in male residents. Contemporary residents were more likely than their predecessors to agree with negative perceptions of cardiology. Conclusions and Relevance: This survey study found that both male and female residents place a high value on support for optimal work-life balance; these preferences have intensified over the past decade and factor into career choice. Negative perceptions of cardiology persist and, in some aspects, are worsening. Improving the culture of cardiology may make this specialty a more attractive career choice for all.


Asunto(s)
Cardiología , Internado y Residencia , Humanos , Masculino , Femenino , Adulto , Estudios Prospectivos , Medicina Interna/educación , Selección de Profesión , Cardiología/educación
18.
JACC Cardiovasc Interv ; 15(24): 2523-2536, 2022 12 26.
Artículo en Inglés | MEDLINE | ID: mdl-36121247

RESUMEN

BACKGROUND: Severe symptomatic degenerative mitral regurgitation (DMR) has a poor prognosis in the absence of treatment, and new transcatheter options are emerging. OBJECTIVES: The CLASP IID (Edwards PASCAL Transcatheter Valve Repair System Pivotal Clinical Trial) randomized trial (NCT03706833) is the first to evaluate the safety and effectiveness of the PASCAL system compared with the MitraClip system in patients with significant symptomatic DMR. This report presents the primary safety and effectiveness endpoints for the trial. METHODS: Patients with 3+ or 4+ DMR at prohibitive surgical risk were assessed by a central screening committee and randomized 2:1 (PASCAL:MitraClip). Study oversight also included an echocardiography core laboratory and a clinical events committee. The primary safety endpoint was the composite major adverse event rate at 30 days. The primary effectiveness endpoint was the proportion of patients with mitral regurgitation (MR) ≤2+ at 6 months. RESULTS: A prespecified interim analysis in 180 patients demonstrated noninferiority of the PASCAL system vs the MitraClip system for the primary safety and effectiveness endpoints of major adverse event rate (3.4% vs 4.8%) and MR ≤2+ (96.5% vs 96.8%), respectively. Functional and quality-of-life outcomes significantly improved in both groups (P < 0.05). The proportion of patients with MR ≤1+ was durable in the PASCAL group from discharge to 6 months (PASCAL, 87.2% and 83.7% [P = 0.317 vs discharge]; MitraClip, 88.5% and 71.2% [P = 0.003 vs discharge]). CONCLUSIONS: The CLASP IID trial demonstrated safety and effectiveness of the PASCAL system and met noninferiority endpoints, expanding transcatheter treatment options for prohibitive surgical risk patients with significant symptomatic DMR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Calidad de Vida , Resultado del Tratamiento
19.
J Am Coll Cardiol ; 80(8): 783-800, 2022 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-35595203

RESUMEN

BACKGROUND: The impact of aortic valve replacement (AVR) on progression/regression of extravalvular cardiac damage and its association with subsequent prognosis is unknown. OBJECTIVES: The purpose of this study was to describe the evolution of cardiac damage post-AVR and its association with outcomes. METHODS: Patients undergoing transcatheter or surgical AVR from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were pooled and classified by cardiac damage stage at baseline and 1 year (stage 0, no damage; stage 1, left ventricular damage; stage 2, left atrial or mitral valve damage; stage 3, pulmonary vasculature or tricuspid valve damage; and stage 4, right ventricular damage). Proportional hazards models determined association between change in cardiac damage post-AVR and 2-year outcomes. RESULTS: Among 1,974 patients, 121 (6.1%) were stage 0, 287 (14.5%) stage 1, 1,014 (51.4%) stage 2, 412 (20.9%) stage 3, and 140 (7.1%) stage 4 pre-AVR. Two-year mortality was associated with extent of cardiac damage at baseline and 1 year. Compared with baseline, cardiac damage improved in ∼15%, remained unchanged in ∼60%, and worsened in ∼25% of patients at 1 year. The 1-year change in cardiac damage stage was independently associated with mortality (adjusted HR for improvement: 0.49; no change: 1.00; worsening: 1.95; P = 0.023) and composite of death or heart failure hospitalization (adjusted HR for improvement: 0.60; no change: 1.00; worsening: 2.25; P < 0.001) at 2 years. CONCLUSIONS: In patients undergoing AVR, extent of extravalvular cardiac damage at baseline and its change at 1 year have important prognostic implications. These findings suggest that earlier detection of aortic stenosis and intervention before development of irreversible cardiac damage may improve global cardiac function and prognosis. (PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - XT Intermediate and High Risk [PII A], NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII B [PARTNERII B], NCT02184442; and PARTNER 3 Trial: Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [P3], NCT02675114).


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Pronóstico , Factores de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
20.
JACC Cardiovasc Imaging ; 15(5): 747-760, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35324429

RESUMEN

OBJECTIVES: The purpose of this study was to compare the American Society of Echocardiography (ASE) algorithm for assessing mitral regurgitation (MR) to cardiac magnetic resonance (CMR) and left ventricular (LV) remodeling following mitral intervention. BACKGROUND: The ASE recommends integrating multiple echocardiographic parameters for assessing MR. The ASE guidelines include an algorithm that weighs the parameters and highlights those considered indicative of definitely mild or definitely severe MR. METHODS: We prospectively enrolled 152 (age 62 ± 13 years; 59% male) patients with degenerative MR who underwent ASE algorithm-guided echocardiographic and CMR grading of MR severity. Using the ASE algorithm, patients were graded as definitely mild, grade I, grade II, grade III, grade IV, or definitely severe MR. CMR MR volume was graded as mild (<30 mL), grade II moderate (30-44 mL), grade III moderate (45-59 mL), or severe (≥60 mL). A subgroup of 63 patients underwent successful mitral intervention, of whom 48 had postintervention CMR. RESULTS: Only 52% of patients with definitely severe MR by the ASE algorithm had severe MR by CMR, and 10% had mild MR by CMR. There was an increase in post mitral intervention LV reverse remodeling with worsening MR severity using CMR (P < 0.0001) but not the ASE algorithm (P = 0.07). Severe MR by CMR was an independent predictor of post mitral intervention LV reverse remodeling and definitely severe MR by the ASE algorithm was not. CONCLUSIONS: In patients with degenerative MR, agreement between CMR and the ASE algorithm was suboptimal. Severe MR by CMR was an independent predictor of post mitral intervention LV reverse remodeling, whereas definitely severe MR by the ASE algorithm was not. These findings suggest an important role for CMR in surgical decision making in degenerative MR. (Comparison Study of Echocardiography and Cardiovascular Magnetic Resonance Imaging in the Assessment of Mitral and Aortic Regurgitation; NCT04038879).


Asunto(s)
Insuficiencia de la Válvula Mitral , Anciano , Algoritmos , Ecocardiografía , Femenino , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Estados Unidos , Remodelación Ventricular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...